Wiring Diagram 1(2.6 KB)   Wiring Diagram 2(1.8 KB)

Resolver Cables - Vacuum Rated Motors

Standard Configuration is 8 Individual Lead Wires
Minimum 12 inches in Length
Motor modelWire sizeWire diameter (Inches)
U11220.0281
Cable information: When optional cables are ordered on U11 motors, it is necessary to specify series or parallel connections. Since there is not enough space inside the size 11 motor to install a cable, optional cable when ordered, is connected on the exterior of the motor with in-line splices.
Empire Magnetics Part number 00-0510-0001 four conductors of 22 AWG, with overall shield and jacket, nominal cable OD .163 inches, minimum bend radius .815 inches. Stranded silver-coated copper conductors, insulated with extruded TFE Teflon. Color-coded, cabled, silver-plated copper braid shield. White TFE Teflon tape-wrapped jacket mil-w-16878/4, temp rating -65° to 200° C, voltage: 600V (RMS)